DR Series Single Output Industrial DIN Rail Power Supply
Features
1. Universal AC input/Full range
2. Protections: Short circuit / Overload / Over voltage
3. Cooling by free air convection
4. Can be installed on DIN rail TS-35/7.5 or 15
5. Isolation class I
6. LED indicator for power on
7. 100% full load burn-in test
8. 2 years warranty
Technical Parameters
MODEL |
DR-45-5 |
DR-45-12 |
DR-45-15 |
DR-45-24 |
|
OUTPUT |
DC VOLTAGE |
5V |
12V |
15V |
24V |
RATED CURRENT |
5A |
3.5A |
2.8A |
2A |
|
CURRENT RANGE |
0-5A |
0-3.5A |
0-2.8A |
0-2A |
|
RATED POWER |
25W |
42W |
42W |
48W |
|
RIPPLE & NOISE (max.) Note.2 |
100mVp-p |
200mVp-p |
240mVp-p |
480mVp-p |
|
VOLTAGE ADJ. RANGE |
4.75-5.5V |
10.8-13.2 V |
13.5-16.5V |
21.6-26.4V |
|
VOLTAGE TOLERANCE Note.3 |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
|
LINE REGULATION |
+ 1.0% |
+ 1.0% |
+ 1.0% |
±1.0% |
|
LOAD REGULATION |
+ 1.0% |
+ 1.0% |
±1.0% |
±1.0% |
|
SETUP, RISE TIME |
800ms, 60ms/230VAC at full load |
||||
HOLD UP TIME (Typ.) |
60ms/230VAC at full load |
||||
INPUT |
VOLTAGE RANGE |
85 ~ 264VAC 120-370VDC |
|||
FREQUENCY RANGE |
47 ~ 63Hz |
||||
EFFICIENCY (Typ.) |
72% |
77% |
77% |
80% |
|
AC CURRENT (Typ.) |
1.5A/115VAC 0.75A/230VAC |
||||
INRUSH CURRENT (Typ.) |
COLD START 28A/115VAC,56A/230VAC |
||||
LEAKAGE CURRENT |
<1mA/240VAC |
||||
PROTECTION |
OVERLOAD |
105 -150% rated output power |
|||
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
|||||
OVERVOLTAGE |
5.75-6.75V |
13.8-16.2V |
17.25-20.25V |
27.6-32.4V |
|
Protection type: Shut off o/p voltage, clamping by zener diode |
|||||
OVER TEMPERATURE |
Tj 135°C typically (U1) detect on heat sink of power transistor |
||||
Protection type: Shut down o/p voltage, re-power on to recover |
|||||
ENVIRONMENT |
WORKING TEMP. |
-10 ~ +50°C (Refer to "Derating Curve") |
|||
WORKING HUMIDITY |
20 - 90% RH non-condensing |
||||
STORAGE TEMP., HUMIDITY |
-20 ~ +85°C, 10 ~ 95% RH |
||||
TEMP. COEFFICIENT |
±0.03%/°C (0 ~ 50°C) |
||||
VIBRATION |
10 - 500Hz, 2G 10min./1 cycle, period for60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
UL508, TUV EN60950-1 approved |
|||
WITHSTAND VOLTAGE |
l/P-0/P:1.5KVAC l/P-FG:1.5KVAC 0/P-FG:0.5KVAC |
||||
ISOLATION RESISTANCE |
l/P-O/P, l/P-FG, 0/P-FG:100M Ohms / 500VDC / 25" |
||||
EMC EMISSION |
Compliance to EN55011.EN55022 (CISPR22), EN61000-3-2.-3 |
||||
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A |
||||
OTHERS |
MTBF |
364.6K hrs min. MIL-HDBK-217F (25"C) |
|||
DIMENSION |
93*78*67mm (L*W*H) |
||||
PACKING |
0.31 Kg; 48pcs/17.5Kg/1.3CUFT |
||||
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. 3.Tolerance : includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
Contact: Henry Zhou
Phone: +86-13626551830
Tel: +86-577-55773828
Whatsapp: +86-13626551830
Email: reelen@reelen.com.cn
Add: Xiangyang Industrial Zone,Liushi Town, Yueqing, Zhejiang, China. 325619