DR Series Single Output Industrial DIN Rail Power Supply

  • 240W Single Output Industrial DIN Rail Power Supply (Model: DRP-240-12/24/48)
240W Single Output Industrial DIN Rail Power Supply (Model: DRP-240-12/24/48)

240W Single Output Industrial DIN Rail Power Supply (Model: DRP-240-12/24/48)

  • Input: 90~132VAC/170~264VAC by Switch
  • Modulation System: PWM
  • MTBF: 432.1Khrs min. MIL-HDBK-217F (25'C)
  • Safety Standard: En60950
  • Description:
  • INQUIRY   EMAIL

DR Series Single Output Industrial DIN Rail Power Supply






Features

1. Universal AC input/Full range
2. Protections: Short circuit / Overload / Over voltage
3. Cooling by free air convection
4. Can be installed on DIN rail TS-35/7.5 or 15
5. Isolation class I
6. LED indicator for power on
7. 100% full load burn-in test
8. 2 years warranty


 

Technical Parameters


 MODEL

DRP-240-12

DRP-240-24

DRP-240-48

 
 
 
 
 
    OUTPUT
 
 
 
 

 

DC VOLTAGE

12V

24 V

48V

RATED CURRENT

20A

10A

5A

CURRENT RANGE

0-20A

0-10A

0-5A

RATED POWER

240W

240W

240W

RIPPLE & NOISE (max.) Note.2

80mVp-p

80mVp-p

150mVp-p

VOLTAGE ADJ. RANGE

10.8-13.2V

21.6-26.4V

43.2 - 52.8V

VOLTAGE TOLERANCE Note.3

±1.0%

±1.0%

±1.0%

LINE REGULATION

±0.5%

±0.5%

±0.5%

LOAD REGULATION

±1.0%

±1.0%

±1.0%

SETUP, RISE TIME

800ms, 40ms/230VAC    800ms, 40ms/115VAC at full load

HOLD UP TIME (Typ.)

20ms/230VAC    20ms/115VAC at full load

 
 
     INPUT
 
 

 

VOLTAGE RANGE

90 -132VAC/170 - 264VAC by switch,240 - 370VDC

FREQUENCY RANGE

47~63Hz

EFFICIENCY (Typ.)

80%

84%

85%

AC CURRENT (Typ.)

3.5A/115VAC   1.8A/230VAC

INRUSH CURRENT (Typ.)

COLD START 30A/115VAC   60A/230VAC

LEAKAGE CURRENT

<3.5mA/240VAC

 
 
PROTECTION
 

 

OVERLOAD

105 -150% rated output power

Protection type: Constant current limiting, recovers automatically after fault condition is removed

OVERVOLTAGE

15-16.5V

29 - 33V

58 -65V

Protection type: Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

100"C ±5"C (TSW1)

 

 

Protection type: Shut down o/p voltage, recovers automatically after temperature goes down

 
ENVIRONMENT

 

WORKING TEMP.

-10 - +60"C (Refer to "Derating Curve")

WORKING HUMIDITY

20 - 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-20 - +85 "C, 10 - 95% RH

TEMP. COEFFICIENT

±0.03%/"C (0-50'C)

VIBRATION

10 - 500Hz, 2G 10min./1 cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6

 
    SAFETY &
        EMC
    (Note 4)

 

SAFETY STANDARDS

UL508, UL60950-1, TUV EN60950-1 approved

WITHSTAND VOLTAGE

l/P-0/P:3KVAC l/P-FG:1.5KVAC 0/P-FG:0.5KVAC

ISOLATION RESISTANCE

l/P-O/P, l/P-FG, 0/P-FG:100M Ohms/500VDC/25,C/70% RH

EMC EMISSION

Compliance to EN55011 .EN55022 (CISPR22) Class B, EN61000-3-2.-3

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A

 
    OTHERS

 

MTBF

432.1Khrs min. MIL-HDBK-217F (25'C)

DIMENSION

125.5*125.2*100mm (W*H*D)

PACKING

1.2Kg; 10pcs/12.7Kg/1.29CUFT

    NOTE

1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25'C of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor.
3.Tolerance : includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

Inquiry:

Categories

CONTACT US

Contact: Henry Zhou

Phone: +86-13626551830

Tel: +86-577-55773828

Whatsapp: +86-13626551830

Email: reelen@reelen.com.cn

Add: Xiangyang Industrial Zone,Liushi Town, Yueqing, Zhejiang, China. 325619