DR Series Single Output Industrial DIN Rail Power Supply

  • 60W Single Output Industrial DIN Rail Power Supply (Model: DR-60-12/24/48)
60W Single Output Industrial DIN Rail Power Supply (Model: DR-60-12/24/48)

60W Single Output Industrial DIN Rail Power Supply (Model: DR-60-12/24/48)

  • Input: 85 ~ 264VAC 120 ~ 370VDC
  • Modulation System: PWM
  • MTBF: 216.2K hrs min. MIL-HDBK-217F (25
  • Safety Standard: En60950
  • Description:
  • INQUIRY   EMAIL

DR Series Single Output Industrial DIN Rail Power Supply







Features

1. Universal AC input/Full range
2. Protections: Short circuit / Overload / Over voltage
3. Cooling by free air convection
4. Can be installed on DIN rail TS-35/7.5 or 15
5. Isolation class I
6. LED indicator for power on
7. 100% full load burn-in test
8. 2 years warranty


Technical Parameters


MODEL

DR-60-5

DR-60-12

DR-60-15

DR-60-24






OUTPUT





DC VOLTAGE

5V

12V

15V

24V

RATED CURRENT

6.5A

4.5A

4A

2.5A

CURRENT RANGE

0-6.5A

0-4.5A

0-4A

0-2.5A

RATED POWER

32.5W

54W

60W

60W

RIPPLE & NOISE (max.) Note.2

80mVp-p

120mVp-p

120mVp-p

150mVp-p

VOLTAGE ADJ. RANGE

4.75-5.5V

11.1 -13.2V

13.5-16.5V

21.6-26.4V

VOLTAGE TOLERANCE Note.3

±2.0%

±1.0%

±1.0%

±1.0%

LINE REGULATION

±1.0%

±1.0%

±1.0%

±1.0%

LOAD REGULATION

±1.0%

±1.0%

±1.0%

±1.0%

SETUP, RISE TIME

100ms, 30ms/230VAC 200ms, 30ms/115VAC at full load

HOLD UP TIME (Typ.)

100ms/230VAC 23ms/115VAC at full load



INPUT


VOLTAGE RANGE

88 - 264VAC 124-370VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

76%

82%

83%

84%

AC CURRENT (Typ.)

1.2A/115VAC 0.8A/230VAC

INRUSH CURRENT (Typ.)

COLD START 18A/115VAC

36A/230VAC




PROTECTION


OVERLOAD

105 -160% rated output power

Protection type: Constant current limiting, recovers automatically after fault condition is removed

OVERVOLTAGE

5.75-6.9V

13.8-16.2V

17.25-20.25V

27.6-32.4V

Protection type: Shut down o/p voltage, re-power on to recover



ENVIRONMENT


WORKING TEMP.

-20 - +60'C (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85'C, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/-C(0~50-C)

VIBRATION

10 - 500Hz, 2G 10min./1 cycle, period for60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6


SAFETY &
EMC
(Note 4)


SAFETY STANDARDS

UL60950-1, TUV EN60950-1 approved, Design refer to EN50178

WITHSTAND VOLTAGE

l/P-0/P:3KVAC

ISOLATION RESISTANCE

l/P-0/P:100M Ohms / 500VDC / 25'C/ 70% RH

EMC EMISSION

Compliance to EN55011, EN55022 (CISPR22) Class B, EN61000-3-2,-3

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A


OTHERS


MTBF

216.2K hrs min. MIL-HDBK-217F (25"C)

DIMENSION

78*93*56mm (W*H*D)

PACKING

0.3Kg; 48pcs/15.4Kg/1.02CUFT
NOTE
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 To of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor.
3.Tolerance : includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.


Inquiry:

Categories

CONTACT US

Contact: Henry Zhou

Phone: +86-13626551830

Tel: +86-577-55773828

Whatsapp: +86-13626551830

Email: reelen@reelen.com.cn

Add: Xiangyang Industrial Zone,Liushi Town, Yueqing, Zhejiang, China. 325619