DR Series Single Output Industrial DIN Rail Power Supply
Features
1. Universal AC input/Full range
2. Protections: Short circuit / Overload / Over voltage
3. Cooling by free air convection
4. Can be installed on DIN rail TS-35/7.5 or 15
5. Isolation class I
6. LED indicator for power on
7. 100% full load burn-in test
8. 2 years warranty
Technical Parameters
MODEL |
DR-120-12 |
DR-120-24 |
DR-120-48 |
|
OUTPUT
|
DC VOLTAGE |
12V |
24 V |
48V |
RATED CURRENT |
10A |
5A |
2.5A |
|
CURRENT RANGE |
0-10A |
0-5A |
0-2.5A |
|
RATED POWER |
120W |
120W |
120W |
|
RIPPLE & NOISE (max.) Note.2 |
80mVp-p |
80mVp-p |
100mVp-p |
|
VOLTAGE ADJ. RANGE |
12- 14V |
24-28V |
48 - 53V |
|
VOLTAGE TOLERANCE Note.3 |
±2.0% |
±1.0% |
±1.0% |
|
LINE REGULATION |
±0.5% |
±0.5% |
±0.5% |
|
LOAD REGULATION |
±1.0% |
±1.0% |
±1.0% |
|
SETUP, RISE TIME |
500ms, 70ms/230VAC 500ms, 70ms/115VAC at full load |
|||
HOLD UP TIME (Typ.) |
36ms/230VAC 32ms/115VAC at full load |
|||
INPUT
|
VOLTAGE RANGE |
85 ~ 264VAC 120 ~ 370VDC |
||
FREQUENCY RANGE |
47~63Hz |
|||
EFFICIENCY (Typ.) |
80% |
84% |
85% |
|
AC CURRENT (Typ.) |
2.6A/115VAC 1.6A/230VAC |
|||
INRUSH CURRENT (Typ.) |
COLD START 20A/115VAC 40A/230VAC |
|||
LEAKAGE CURRENT |
<3.5mA/240VAC |
|||
PROTECTION
|
OVERLOAD |
105 -150% rated output power |
||
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
||||
OVERVOLTAGE |
15-16.5V |
29 - 33V |
58 -65V |
|
Protection type: Shut down o/p voltage, re-power on to recover |
||||
OVER TEMPERATURE |
85"C ±5"C (TSW1) |
90"C+5"C(TSW1) |
90'C ±5"C(TSW1) |
|
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down |
||||
ENVIRONMENT
|
WORKING TEMP. |
-10 - +60"C (Refer to "Derating Curve") |
||
WORKING HUMIDITY |
20 - 90% RH non-condensing |
|||
STORAGE TEMP., HUMIDITY |
-20 - +85 "C, 10 - 95% RH |
|||
TEMP. COEFFICIENT |
±0.03%/"C (0-50'C) |
|||
VIBRATION |
10 - 500Hz, 2G 10min./1 cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
|||
SAFETY & EMC (Note 4)
|
SAFETY STANDARDS |
UL508, UL60950-1, TUV EN60950-1 approved |
||
WITHSTAND VOLTAGE |
l/P-0/P:3KVAC l/P-FG:1.5KVAC 0/P-FG:0.5KVAC |
|||
ISOLATION RESISTANCE |
l/P-O/P, l/P-FG, 0/P-FG:100M Ohms/500VDC/25,C/70% RH |
|||
EMC EMISSION |
Compliance to EN55011 .EN55022 (CISPR22) Class B, EN61000-3-2.-3 |
|||
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A |
|||
OTHERS
|
MTBF |
432.1Khrs min. MIL-HDBK-217F (25'C) |
||
DIMENSION |
65.5*125.2*100mm (W*H*D) |
|||
PACKING |
0.79Kg; 20pcs/16.5Kg/1.29CUFT |
|||
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25'C of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. 3.Tolerance : includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |