PID Intelligent Temperature Controller

  • Double Output Pid Intelligent Temperature Controller (Model: CH402)
  • Double Output Pid Intelligent Temperature Controller (Model: CH402)
Double Output Pid Intelligent Temperature Controller (Model: CH402)Double Output Pid Intelligent Temperature Controller (Model: CH402)

Double Output Pid Intelligent Temperature Controller (Model: CH402)

  • Control Type: PID or ON/OFF
  • Input Type: K,J,PT100 or Others
  • Output Type: Relay,SSR,4-20mA,0-10V
  • Alarm: 1 or 2
  • Description: REELEN Digital PID temperature controller thermostat CH102, CH402,CD701(CH702),CH902 ; PID with self-tuning; Selectable input. CH/CD series intelligent temperature controllers use computer chip as
  • INQUIRY   EMAIL
CH/CD Series PID Intelligent Temperature Controller



Application

REELEN Digital PID temperature controller thermostat CH102, CH402,CD701(CH702),CH902 ; PID with self-tuning; Selectable input.

CH/CD series intelligent temperature controllers use computer chip as the main control unit.The controllers have perfectly designed circuit,mature control program,digital PID and self tuning function,fuzzy control mode etc,which endows the equipments with advantages of high measurement accuracy,correct and stable temperature control,strong antiinterference and simple operation.They are widely used in chemical,ceramic,light,metallurgical,petrochemical and plastic industries as substitution of traditional pointer meter.



Main Function

1) Selft-tuning;
2) Universal input;
3) LED screeen display;
4) Heating,cooling,alarm;



General Electrical Data

Rated voltage: 180-240VAC 50/60Hz or 85-260VAC 50/60Hz
Power consumption: ≤5W
Accuracy: 0.5%FS
Display accuracy: 1°c
Ambient temperature: 0°c - 50°c
Relative humidity: 35% - 85% (no condensation)
Connection type: terminals
S/N Name Descriptions
1 Outline(mm) 102:48*48   402:48*96
501:96*48   702:72*72
902:96*96
2 Control type 0:PID control        1: step control
3 Input type 1:thermocouple input       2:RTD input
4 Output type 1: break output
5 Refrigerating type 0:no refrigerating    1: step refrigerating   2:proportional refrigerating
6 Alam type 0:no alarm    1:upper limit alarm    2:low limit alarm
7 Input type 1:K     2:E    3:Pt100     4:Cu50     6:J
8 Output type 1:relay contact switch output    2:logic level output(used to control SSR)   3:4-20mA
9 Alam mode Deviation high alarm
Deviation low alarm
Deviation high/low alarm
Band alarm
Process high alarm
Process low alarm
10 Alam output 1: 1 alarm output   2:2 alarm output
11 Temperature range 1: 0°c-100 °c    2: 0 °c-150 °c     3: 0 °c-400 °c
4:0 °c-600 °c    5: 0 °c-800 °c     6: 0 °c-999 °c
12 Power supply 100-260VAC
Note:
· Only clean the instrument when power off.
· Please use a soft cloth or cotton paper to clean up the stain on the display.
· Do not clean up or touch the display by hard matters in case of  any scrath.
· Never use sharp & hard matters such ass screwdrivers or ball pan to touch the buttons on the panel,in case of any scrath or damage.




Inquiry:

Categories

CONTACT US

Contact: Henry Zhou

Phone: +86-13626551830

Tel: +86-577-55773828

Whatsapp: +86-13626551830

Email: reelen@reelen.com.cn

Add: Xiangyang Industrial Zone,Liushi Town, Yueqing, Zhejiang, China. 325619